INSTC_V8 PDF Pass Leader, INSTC_V8 Latest Real Test [Q78-Q97]

Share

INSTC_V8 PDF Pass Leader, INSTC_V8 Latest Real Test

Valid INSTC_V8 Test Answers & INSTC_V8 Exam PDF

NEW QUESTION # 78
When installing optical fiber cable in a cable tray with a 15 cm (6 in) inside depth, which of the following support practices is MOST appropriate to adhere to bend radius requirements?

  • A. Maintain at least twice the manufacturer's recommended bend radius by using fittings or supports at each transition point.
  • B. Place cables loosely along the tray without ties.
  • C. Use Velcro straps and secure them at 2 m (6 ft) intervals.
  • D. Tie-wrap the cables tightly at every 30 cm (12 in).

Answer: A


NEW QUESTION # 79
Which of the following quantifies the bandwidth of a cabling system in a frequency range of interest?

  • A. Megahertz
  • B. Megabits
  • C. Kilowatt hours
  • D. Volt-amperes

Answer: A


NEW QUESTION # 80
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?

  • A. TR
  • B. Work area
  • C. ER
  • D. EF

Answer: A


NEW QUESTION # 81
A purple backboard should be used to identify ________?

  • A. Horizontal cable
  • B. Common equipment
  • C. Network connections
  • D. Demarcation point

Answer: B


NEW QUESTION # 82
Which of the following refers to a set of rules issued by a governmental body at the state level within the US?

  • A. Best Practices
  • B. Applications
  • C. Regulations
  • D. Guidelines

Answer: C


NEW QUESTION # 83
Which statement is TRUE concerning campus backbone installations between buildings that share a common building entrance facility?

  • A. Each building must independently ground its backbone cable to a separate earth ground
  • B. Different shielded cable types can be directly bonded together without a grounding kit
  • C. Optical fiber cable should be grounded at both ends using a single conductor
  • D. The best practice is to install at least two diverse pathways to allow for redundancy

Answer: D


NEW QUESTION # 84
Which of the following should be used to install plywood in a telecommunications room if the edge of the board does NOT align with the wall studs?

  • A. Toggle bolts
  • B. Galvanized screws
  • C. Metal nails

Answer: A


NEW QUESTION # 85
You are terminating a category 3 cable. What is the maximum permissible amount of untwisting?

  • A. 25 mm (1")
  • B. 38 mm (1.5")
  • C. 75 mm (3")
  • D. 100 mm (4")

Answer: C


NEW QUESTION # 86
What is the minimum recommended height that should be used when mounting a plywood back board in a telecommunication space?

  • A. AFF 300 mm (12") AFF
  • B. 100 mm (4")
  • C. AFF 200 mm (8")
  • D. AFF 150 mm (6")

Answer: C


NEW QUESTION # 87
Which of the following connector styles is presently used within optical fiber cabling systems (i.e., it is NOT a legacy connector)?

  • A. Biconic
  • B. Small form factor (SFF)
  • C. Mechanical transfer RJ
  • D. SMA 906

Answer: B


NEW QUESTION # 88
What is the maximum pull force for four-strand optical fiber?

  • A. 222N (50 lbf)
  • B. 880 N (200 lbf)
  • C. 330 N (75lbf)

Answer: A


NEW QUESTION # 89
Two truck drivers are communicating over a Citizens Band (CB) radio. Only one driver can send a message at a time with this system.
What type of transmission method is used in this example?

  • A. Full duplex
  • B. Half-duplex
  • C. Simplex

Answer: B


NEW QUESTION # 90
A radio station transmits an omnidirectional signal that is received by multiple radios. What type of transmission method is used in this example?

  • A. Half-duplex
  • B. Full-duplex
  • C. Simplex

Answer: C


NEW QUESTION # 91
What is the recommended thickness for plywood that will be mounted on the walls of a telecommunications room?

  • A. 25 mm (1")
  • B. 19 mm (3/4")
  • C. 12.7 mm (1/2")
  • D. 32 mm (1-1/4")

Answer: B


NEW QUESTION # 92
What is the specified performance level for Category 6 cable?

  • A. 600 MHz
  • B. 500 MHz
  • C. 250 MHz
  • D. 100 MHz

Answer: C


NEW QUESTION # 93
When installing Category 6 cable, which is the MOST sensitive parameter to be safeguarded against during the termination process?

  • A. Pair untwist within 13 mm (0.5 in) from the termination point
  • B. Insertion loss due to excessive pulling tension
  • C. Color code mismatch in the patch panel and jack
  • D. Cable jacket diameter mismatch with the connector

Answer: A


NEW QUESTION # 94
If a horizontal cable is placed in an open ceiling return-air plenum, which cable rating is REQUIRED by NFPA and BICSI guidelines?

  • A. CATVX
  • B. CM
  • C. CMR
  • D. CMP

Answer: D


NEW QUESTION # 95
The minimum recommended separation distance between twisted-pair communications cabling and electrical power cabling in open air (when power runs in parallel) per BICSI/TIA guidelines is typically ______.

  • A. 50 mm (2 in)
  • B. 300 mm (12 in)
  • C. 610 mm (24 in)
  • D. 150 mm (6 in)

Answer: B


NEW QUESTION # 96
Which of the following describes a nonmechanical firestop system that forms a hard char when exposed to flame?

  • A. Elastomeric
  • B. Ablative
  • C. Endothermic
  • D. Intumescent

Answer: B


NEW QUESTION # 97
......

INSTC_V8 Dumps Ensure Your Passing: https://www.test4engine.com/INSTC_V8_exam-latest-braindumps.html

INSTC_V8 exam dumps and online Test Engine: https://drive.google.com/open?id=1ZIoUBfNI_gmeuc37sMZyzukRuEPgzGh0