NEW QUESTION 51
To modify the micro-module view of ECC800,users need to log in the WebUI as as admin.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 52
2.4G antenna of ECC800 should be connected to ( ).

  • A. RS485 port
  • B. 3G/4G antenna interface
  • C. RF_ZA line interface
  • D. DO output dry contact

Answer: B

 

NEW QUESTION 53
The default user name of ECC800 is admin, and admin has permission to operate on the ECC800 WebUI.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 54
On the NetEco interface, a modular can only bind () ECC800 devices.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 55
When four UPS2000-G-20K parallel setting is "3+1", the capacity of the system is ( ) KVA.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 56
The Maximum distance of WIFI coverage for WIFI converter is ( )m.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 57
The DX air cooled air conditioner has no limit on the installation distance.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 58
The NetEco system can customize the alarm sound for different levels of alarms.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 59
On the ( ) menu of NetEco App. PUE information can be displayed.

  • A. Power
  • B. Aisle
  • C. Alarm
  • D. Log management

Answer: A,B,C,D

 

NEW QUESTION 60
DuringNetCol5000-C commissioning, the opening of the water valve needs to be adjusted to minimum when you inject water and exhaust air.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 61
The EPO ports of UPS5000-E can be selected to normal open or normal close.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 62
When the UPS5000-E (), boot will automatically run the Quick Setup Wizard. (Multiple Choice)

  • A. First boot
  • B. Start after recovery failure
  • C. Turn it off and then on.
  • D. The device is turned on again after the factory settings are restored.

Answer: A,D

 

NEW QUESTION 63
Commissioning UPS5000-E parallel system, the reason for triggering EPO ports is ().

  • A. To protect batteries and prevent battery discharge
  • B. To protect loads against electric shock and ensure safety
  • C. To power off the loads and prevent damage to the loads.
  • D. To disconnect the output and set the parallel parameters

Answer: C

 

NEW QUESTION 64
Which of the following options is a natural cooling system?

  • A. Water-cooled cold air conditioning system
  • B. Air-cooled direct expansion air conditioning system
  • C. Water-cooled cold water air conditioning system
  • D. Direct ventilation air conditioning system

Answer: D

 

NEW QUESTION 65
The work modes of rotary wheel free cooling solution are ().

  • A. Direct ventilation mode
  • B. Mixed mode
  • C. Compressor cooling mode
  • D. Free cooling mode

Answer: B,C,D

 

NEW QUESTION 66
When you create a camera in NetEco, you need to get () in addition to the IP address of the camera.

  • A. Camera pixels
  • B. Camera brightness
  • C. Camera installation location
  • D. Camera coding

Answer: D

 

NEW QUESTION 67
In the battery model 6-GFM-150, 150 indicates the battery ().

  • A. Maximum capacity
  • B. Rated capacity
  • C. Minimum capacity
  • D. Actual capacity

Answer: B

 

NEW QUESTION 68
UPS2000-A-(1-3kVA) closes the mains input switch and directly enters the bypass working state.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 69
Where is the recommended installation location for the Smart ETH socket?

  • A. Side of the cable trough on the top of the cabinet
  • B. Inside the network cabinet
  • C. Control skylight
  • D. Inside the threshold

Answer: A

 

NEW QUESTION 70
Domains can be created in NetEco, such as campuses, buildings, machine rooms, containers, etc.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 71
For the half sized NetCol5000-A25 kW, when preserve positive pressure, the pressure is ( ) MPa

  • A. 0
  • B. 1
  • C. 2.5
  • D. 0.8

Answer: B

 

NEW QUESTION 72
When turning on the maintenance bypass switch of UPS5000-E, to make sure loads continue to be powered, which should be noted?

  • A. If the UPS works in normal mode you can turn on the maintenance bypass switch
  • B. Shutdown the inverter, switch the UPS to bypass mode and turn on the maintenance bypass switch
  • C. If the UPS works in ECO mode, you can turn on the maintenance bypass switch
  • D. Perform EPO and turn on the maintenance bypass switch

Answer: B

 

NEW QUESTION 73
......